Low-energy cooling
Indirect Evaporative Cooling Systems
Two-stage evaporative cooling designed for Gulf summers. Outdoor air is first cooled in a dry heat exchanger without adding moisture, then finished across evaporative pads, delivering 100% fresh, filtered air at a fraction of the power of compressor cooling.
- 100% fresh air
- ~65% less energy than DX
- No added humidity in stage 1
How the two stages work
Stage 1: indirect
Air splits into two streams. The supply stream passes through dry channels of a counter-flow heat exchanger and is cooled by evaporation in the adjacent wet channels, which are exhausted.
Stage 2: direct
The pre-cooled supply air passes across cellulose pads, where evaporation lowers its temperature further before it enters the building.
Design-day supply air by city
| City | Peak ambient | Supply air |
|---|---|---|
| Doha | 46.1 °C | 18.3 °C |
| Riyadh | 46.1 °C | 14.5 °C |
| Dubai | 45.1 °C | 20.2 °C |
| Jeddah | 43.8 °C | 20.9 °C |
| Kuwait | 49.5 °C | 15.8 °C |
| Muscat | 44.9 °C | 18.6 °C |
| Bahrain | 42.0 °C | 20.4 °C |
Energy comparison at equal duty
| Measure | Indirect evaporative | DX cooling |
|---|---|---|
| Input power | 8.45 kW | 24.14 kW |
| Coefficient of performance | 5.15 | 1.83 |
| Air supplied | 100% fresh, filtered | Mostly recirculated |
Applications
Make-up air & renovations
Fresh-air treatment for existing buildings without new chillers.
Commercial kitchens
Replace exhausted air with cooled fresh air.
Data centres
Free-cooling support that reduces compressor hours.
Warehouses & factories
Comfort cooling for large volumes at low running cost.
Stadiums, mosques & halls
High-occupancy spaces that need high fresh-air rates.
Schools & offices
Better indoor air quality with lower energy bills.
Products in this range
Direct Evaporative Air Cooler
Pad-type evaporative cooler for workshops, warehouses and semi-open areas.
Price and availability on enquiryIndirect Evaporative Cooling Unit
Two-stage indirect-direct evaporative unit supplying 100% fresh, filtered air for large buildings.
Price and availability on enquiryHow we work
Tell us the duty
Share the application, site conditions, drawings or part numbers.
We ask the right questions
An engineer confirms the selection data before anything is priced.
Clear quotation
Price, scope, documentation and delivery set out in writing.
Delivery and support
Supply, installation where agreed, and after-sales follow-up.
Keep exploring
Related products and solutions
Misting Systems
High-pressure mist cooling for outdoor areas, greenhouses and industrial sites.
Odor Control Systems
Neutralising mist for waste, sewage and food sites.
HVAC Services
Fresh-air cooling, ventilation and controls.
Answers before you enquire
Frequently asked questions
Does evaporative cooling work in humid coastal weather?
The indirect stage cools without adding moisture, so performance holds better than direct coolers. Supply temperature rises on very humid days; we size on local design data.
How much water does a unit use?
Water use depends on airflow and climate. We estimate consumption for your city and airflow with the selection, including bleed-off for water quality.
Can it work alongside existing air conditioning?
Yes. It is often installed as a fresh-air pre-cooler so existing DX or chilled-water plant runs for fewer hours.
Send the requirement. Start the right conversation.
Share a part number, a photo, a drawing or a complete BOM. Price, availability, technical scope and delivery are confirmed in your quotation.